Victron energy, Victron CANUSB Interface, Communication and surveillance, SL509 View larger

Victron CANUSB VE.Can to USB interface

SL509

New

0 Product in stock in our warehouse.

10 + Reserved; if you order more, it will be in our warehouse within 3 to 10 days.

After ordering here: 11/28/2026

Excl. VAT: € 384,26

€ 384,26

 tax 0% incl.

Tax incl.

Download

(If the downloaded document needs to be translate in another language: https://translate.google.com/?sl=auto&op=docs )

Data sheet

Manufacturing number ASS030532010

More info

Victron Energy CANUSB VE.Can to USB Interface – Professional USB Communication Adapter for VE.Can Devices

The Victron Energy CANUSB VE.Can to USB Interface (ASS030532010) is a professional communication adapter designed to connect Victron Energy devices equipped with a VE.Can interface directly to a Windows computer via USB.

Developed for installers, service technicians and system integrators, this interface provides a reliable connection between a computer and a Victron VE.Can network, enabling compatible software to communicate with connected equipment and perform supported firmware updates.

The CANUSB adapter is particularly useful for system commissioning, maintenance, firmware management and technical servicing of compatible Victron Energy products.

Direct VE.Can to USB Communication

The Victron CANUSB interface creates a communication bridge between a computer's USB port and the VE.Can communication network used by various Victron Energy devices.

This allows professional users to establish a direct connection to compatible equipment without requiring a separate network communication gateway.

Key advantages include:

  • Direct USB connection between a Windows computer and a VE.Can network.

  • Communication with compatible Victron Energy VE.Can devices.

  • Support for firmware updates using compatible Victron software.

  • Convenient interface for professional installation and servicing.

  • Compact adapter suitable for field service and workshop applications.

Firmware Updates and System Maintenance

The CANUSB interface can be used together with compatible Victron Energy software to update firmware on supported VE.Can devices.

Using the appropriate firmware update software, technicians can connect their computer to the VE.Can network and perform supported maintenance procedures.

This makes the CANUSB adapter a valuable accessory for professional installers and service engineers working with Victron Energy systems.

Firmware update capabilities depend on the connected equipment and the software supported by Victron Energy.

Integrated LED Status Indicator

The CANUSB interface features an integrated red status LED, providing immediate visual information about the connection and communication activity.

The LED indicates three operating conditions:

  • Continuous red light: The adapter is connected to the operating system driver.

  • Slow blinking: A software application has established communication with the adapter.

  • Fast blinking: Data is being transmitted through the connected CAN bus.

These indicators help technicians verify the communication status during installation, configuration and maintenance.

Compatible with Victron VE.Can Equipment

The CANUSB adapter is designed for use with Victron Energy products featuring a VE.Can communication interface.

Examples of compatible VE.Can equipment described in the manufacturer documentation include:

  • Victron Skylla-i battery chargers.

  • Victron BlueSolar MPPT 150/70 solar charge controllers.

  • Victron Lynx Shunt VE.Can.

  • Other Victron Energy products equipped with a compatible VE.Can connection.

The adapter can also be integrated into VE.Can networks containing multiple compatible devices.

Important: The CANUSB interface is designed exclusively for VE.Can communication. It is not compatible with VE.Bus or VE.Net communication ports.

Reliable VE.Can Network Integration

For correct operation, the CANUSB adapter must be connected to a properly configured VE.Can network.

The network requires termination at both ends using the appropriate VE.Can RJ45 terminators.

The CANUSB interface does not supply power to the VE.Can network. Therefore, at least one connected device must provide the necessary network power.

Two VE.Can RJ45 terminators are included with the adapter to support correct network termination.

Windows Computer Connectivity

The CANUSB interface connects to a computer through a standard USB connection.

The manufacturer's supplied manual documents support for the following operating systems:

  • Windows 10 (32-bit and 64-bit).

  • Windows 8.1 (32-bit and 64-bit).

  • Windows 7 (32-bit and 64-bit).

The appropriate CANUSB driver must be installed before connecting the adapter to the computer for the first time.

Note: These operating systems are specified in the manufacturer's 2019 manual. Compatibility with newer Windows versions should be verified using the latest Victron Energy driver information.

Technical Specifications

SpecificationDetails
Manufacturer Victron Energy
Product CANUSB VE.Can to USB Interface
Manufacturer Part Number ASS030532010
Product Type USB to CAN communication interface
Computer Connection USB
Network Communication VE.Can
VE.Can Connection RJ45
Status Indicator Integrated red LED
Firmware Update Support Yes, for supported VE.Can devices
Network Termination Two VE.Can RJ45 terminators included
VE.Can Network Power Supply Not provided by the adapter
Documented Operating Systems Windows 7 / 8.1 / 10 (32/64-bit)
VE.Bus Compatibility No
VE.Net Compatibility No

Package Contents

The Victron Energy CANUSB interface package includes:

  • 1 × Victron CANUSB VE.Can to USB adapter.

  • 2 × VE.Can RJ45 terminators.

  • 1 × Installation and operating manual.

Drivers and software are available separately through the official Victron Energy website.

Typical Applications

The Victron CANUSB interface is suitable for a wide range of professional applications, including:

  • Solar energy installations: Communication and supported firmware maintenance for compatible VE.Can solar charge controllers.

  • Marine and yacht electrical systems: Professional servicing of compatible Victron Energy equipment.

  • Off-grid power systems: Connecting service computers to VE.Can-based installations.

  • Battery charging installations: Maintenance and firmware management of compatible Victron Skylla-i chargers.

  • Professional service workshops: Diagnostic communication and firmware servicing of supported VE.Can devices.

  • System commissioning: Establishing computer communication with compatible VE.Can equipment during installation and maintenance.

Why Choose the Victron Energy CANUSB Interface?

The Victron Energy CANUSB VE.Can to USB Interface provides a practical and professional solution for connecting a Windows computer to a Victron VE.Can communication network.

With its direct USB connectivity, integrated communication status indicator, support for compatible firmware update tools and included network terminators, the adapter is a useful accessory for technicians working with Victron Energy installations.

A professional communication and maintenance interface for reliable access to compatible Victron Energy VE.Can devices.

  • Reviews (0)