Looking for competitive wholesale prices for all your supplies?
Look no further! Dutchmart.nl offers an exclusive B2B environment with attractive wholesale prices for companies and installers.
Register NOW at Dutchmart.nl!
Please note: After registration, our team will check your company details. You will receive access to the B2B platform as:
Please use your official company email address to register. (No Gmail, Yahoo, etc.)
Become a member of Dutchmart.nl and benefit from:
Register today and benefit immediately!
Our systems have detected that you are visiting us from United States.
UK, NON-EU and B2B customers note!
All prices and shipping costs are VAT FREE rated in our webstore. Upon arrival of your order you might be subject for VAT / Duty taxes payments.
SL273
New
1 Product in stock in our warehouse. Products in stock in our warehouse. / 25 + We reserved extra stock from the manufacturer. If you order from us now, the product will be delivered quickly.
Warning: Last items in stock!
Estimated availability and shipping date:
Manufacturing number | BPR048100400 |
The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which
would damage the battery) or before it has insufficient power left to crank the engine.
12/24V auto ranging
The BatteryProtect automatically detects system voltage
Programming made easy
The BatteryProtect can be set to engage / disengage at several different voltages.
The seven segment display will indicate which setting has been chosen.
A special setting for Li-ion batteries
In this mode the BatteryProtect can be controlled by the VE.Bus BMS.
Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual.
Ultra low current consumption
This is important in case of Li-ion batteries, especially after low voltage shutdown.
Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information.
Over voltage protection
To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.
Ignition proof
No relays but MOSFET switches, and therefore no sparks.
Delayed alarm output
The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds.
Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay.
Delayed load disconnect and delayed reconnect
The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected.
The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.